﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Tabriz University of Medical Sciences</PublisherName>
      <JournalTitle>Pharmaceutical Sciences</JournalTitle>
      <Issn>1735-403X</Issn>
      <Volume>32</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2026</Year>
        <Month>10</Month>
        <DAY>31</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>Development of a Probe Based on UiO-66 MOF for Determination of Paclitaxel in Urine Samples</ArticleTitle>
    <FirstPage>623</FirstPage>
    <LastPage>631</LastPage>
    <ELocationID EIdType="doi">10.34172/ps.43560</ELocationID>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Reza</FirstName>
        <LastName>Moharami</LastName>
        <Identifier Source="ORCID">https://orcid.org/0009-0002-4395-1255</Identifier>
      </Author>
      <Author>
        <FirstName>Zahra</FirstName>
        <LastName>Karimzadeh</LastName>
      </Author>
      <Author>
        <FirstName>Yosra</FirstName>
        <LastName>Vaez-Gharamaleki</LastName>
      </Author>
      <Author>
        <FirstName>Jafar</FirstName>
        <LastName>Soleymani</LastName>
      </Author>
      <Author>
        <FirstName>Elaheh</FirstName>
        <LastName>Rahimpour</LastName>
        <Identifier Source="ORCID">https://orcid.org/0009-0001-2304-7632</Identifier>
      </Author>
      <Author>
        <FirstName>Abolghasem</FirstName>
        <LastName>Jouyban</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">10.34172/ps.43560</ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2025</Year>
        <Month>11</Month>
        <Day>29</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2026</Year>
        <Month>04</Month>
        <Day>15</Day>
      </PubDate>
    </History>
    <Abstract>Introduction: Accurate and precise determination of paclitaxel is crucial due to its widespread use as a frontline treatment for various types of cancer, as well as its implementation in various drug delivery strategies. The objective of this study was to validate a facile fluorescent probe utilizing the UiO-66 metal-organic framework (MOF) to quantify paclitaxel in urine samples. Results: In the presence of paclitaxel and proportional to its concentration, the fluorescence intensity of UiO-66 MOF gradually decreased due to the formation a non-fluorescent complex during the interaction of paclitaxel and UiO-66 MOF. This platform demonstrated a linear response within the paclitaxel concentration range of 0.01 to 1.5 μg.mL−1, with a detection limit of 0.007 μg.mL−1. The UiO-66 MOF based probe’s relative standard deviation for five replicated measurements of paclitaxel were 1.4% and 2.6% (n=5) for intra-day and inter-day, respectively. Conclusion: The results indicated that this robust and low-cost fluorescent probe was a promising platform for analyzing paclitaxel in clinical applications.  </Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">UiO-66 MOFs</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Fluorescent probe</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Paclitaxel</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Urine</Param>
      </Object>
    </ObjectList>
  </Article>
</ArticleSet>