﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Tabriz University of Medical Sciences</PublisherName>
      <JournalTitle>Pharmaceutical Sciences</JournalTitle>
      <Issn>1735-403X</Issn>
      <Volume>22</Volume>
      <Issue>2</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2016</Year>
        <Month>06</Month>
        <DAY>30</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>Microextraction Methods for Preconcentration of Aluminium in Urine Samples</ArticleTitle>
    <FirstPage>87</FirstPage>
    <LastPage>95</LastPage>
    <ELocationID EIdType="doi">10.15171/PS.2016.15</ELocationID>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Farzad</FirstName>
        <LastName>Farajbakhsh</LastName>
      </Author>
      <Author>
        <FirstName>Mohammad</FirstName>
        <LastName>Amjadi</LastName>
      </Author>
      <Author>
        <FirstName>Jamshid</FirstName>
        <LastName>Manzoori</LastName>
      </Author>
      <Author>
        <FirstName>Mohammad R.</FirstName>
        <LastName>Ardalan</LastName>
      </Author>
      <Author>
        <FirstName>Abolghasem</FirstName>
        <LastName>Jouyban</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">10.15171/PS.2016.15</ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2016</Year>
        <Month>01</Month>
        <Day>20</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2016</Year>
        <Month>02</Month>
        <Day>20</Day>
      </PubDate>
    </History>
    <Abstract>Background: Analysis of aluminium (Al) in urine samples is required in management of a number of diseases including patients with renal failure. This work aimed to present dispersive liquid-liquid microextraction (DLLME) and ultrasound-assisted emulsification microextraction (USAEME) methods for the preconcentration of ultra-trace amount of aluminum in human urine prior to its determination by a graphite furnace atomic absorption spectrometry (GFAAS). Methods: The microextraction methods were based on the complex formation of Al3+ with 8-hydroxyquinoline. The effect of various experimental parameters on the efficiencies of the methods and their optimum values were studied. Results: Under the optimal conditions, the limits of detection for USAEME-GFAAS and DLLME-GFAAS were 0.19 and 0.30 ng mL−1, respectively and corresponding relative standard deviations (RSD, n=5) for the determination of 40 ng mL−1 Al3+ were 5.9% and 4.9%. Conclusion: Both methods could be successfully used to the analysis of ultra trace concentrations of Al in urine samples of dialysis patients.</Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Aluminum</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Dispersive liquid-liquid microextraction (DLLME)</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Ultrasound-assisted emulsification microextraction</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Graphite furnace atomic absorption spectrometry</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Dialysis patients</Param>
      </Object>
    </ObjectList>
  </Article>
</ArticleSet>